Water Dome®
- Pure Water Replacement Filter -
A highly-compressed block of super-fine activated carbon efficiently removes unwanted contaminants and improves taste. This method of filtration is easy to install, simple to maintain, and has an inexpensive filter to periodically replace.
- Does not remove minerals and trace elements that are essential to good health.
- Does not waste water: 100% of filtered water is available for consumption.
- Does not use electricity: Requires only water pressure to operate.
CAUTION: Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection of the system before or after. Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts.
Replacement instructions for each model below:
Instructions for Counter Top Water Dome®
Model #32
Removing Used Filter Cartridge:
- Rest unit on its side, with the base over the left side of the sink.
- Loosen unit base from housing by using the Filter Replacement Tool. Position the hook end of the tool between the two brass fittings in the base. Steady the housing with your left hand and carefully pull the Filter Replacement Tool toward you with your right hand, turning the unit base counterclockwise. Once loosened, separate the housing from the unit base by turning the housing counterclockwise (BY HAND) while holding the base.
- Remove used filter cartridge from base by turning counterclockwise. Discard small white rubber washer.
- Place used filter in a plastic bag and dispose of properly.
Installing New Filter Cartridges:
- Gently wash the inside of the housing unit with Liquid Concentrate, Mellow Yellow, or a liquid dishwashing detergent. Do not use harsh cleansers, solvents, ammonia, alcohol or acids to clean the unit. Rinse thoroughly to remove soap residue.
- Unwrap new filter cartridge and locate the new rubber washer. Hold the base and put the new white washer in place.
CAUTION: As you are putting the unit back together, avoid damaging large O-ring. Check to see that it is positioned correctly before screwing base back into housing.
- Carefully align the new filter over the threads and turn clockwise until snug, but not too tight.
- Hold the housing inverted to keep the O-ring in place. Carefully align the unit base with the housing threads. Turn the housing counter-clockwise onto the base until snug, but not too tight. HAND TIGHTEN ONLY. DO NOT USE TOOL TO TIGHTEN.
- Turn on COLD WATER ONLY. With a slight pull on the Diverter Button, allow water to run through the filter for approximately 5 minutes as you carefully check all connections for leaks. Let water run for an additional 20 minutes to fully activate the filter cartridge. The Water Dome is now ready for use.
CAUTION: Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection of the system before or after. Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts.
Instructions for Stainless Undercounter Water Dome®
Model #28 & #29
Removing Used Filter Cartridge:
- Be sure water is turned off at shut-off valve. Place a large bowl or pan under Water Dome to catch residual water.
- Open (black) ledge faucet lever to relieve pressure.
- Holding unit base, unscrew black knob until band clamp can be removed. Remove band clamp. Separate unit base from upper housing and dump water into bowl or pan. Set unit base aside.
- Unthread used filter clockwise. Place used filter in a plastic bag and dispose properly.
Installing New Filter Cartridges:
- Gently wash the inside of the housing unit with Liquid Concentrate, Mellow Yellow, or a liquid dishwashing detergent. Do not use harsh cleansers, solvents, ammonia, alcohol or acids to clean the unit. Rinse thoroughly to remove soap residue.
- Unwrap new filter and discard the small white rubber washer that comes with it. This is only used in the Countertop model. Carefully align new filter and turn counterclockwise until snug, but not too tight.
CAUTION: As you are putting the unit back together, avoid damaging large O-ring. Check to see that it is positioned correctly before replacing band clamp.
- Replace bottom half of housing unit and tighten the band clamp.
- Turn on water at shut-off valve. Allow water to run through the filter for approximately 5 minutes as you carefully check all connections for leaks. Let water run for an additional 20 minutes to fully activate the filter cartridge. The Water Dome is now ready for use.
CAUTION: Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection of the system before or after. Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts.
Instructions for Countertop Water Dome®
Model #1710
Removing Used Filter Cartridge:
- Turn the unit upside down in the sink, holding the top of the housing secure. Turn the base counterclockwise. If the base does not come loose, use the enclosed 1/4" unscrewing rod by carefully inserting the rod into the slots located on the outer edge of the base.
Note: Be very careful. FORCE OR PRESSURE on the inflow/outflow elbows may result in DAMAGE to the unit.
- As soon as the base loosens, remove the unscrewing rod and continue to unscrew by hand. The top of the housing should be turned and the base, with hoses attached, held stationary until the housing separates from the base. The dirty filter cartridge will be attached to the base.
- Remove the filter by holding the base stationary and turning the cartridge. DO NOT hold onto or apply pressure to elbow fittings on the base.
- Discard small white rubber washer. Dispose of filter in plastic bag and place in trash for disposal.
Installing a New Filter Cartridge:
- Gently wash inside of the housing unit with Liquid Concentrate, Mellow Yellow, or a liquid dishwashing detergent. Do not use harsh cleansers, solvents, ammonia, alcohol or acids to clean the unit. Rinse thoroughly to remove soap residue.
CAUTION: As you are putting the unit back together, avoid damaging large "O" ring. Check to see that it is positioned correctly before screwing base back into housing.
- Unwrap new filter cartridge and locate the new rubber washer. Hold the base and put the new (white) washer in place.
- Carefully align the new filter over the threads and turn clockwise until snug, but not too tight.
- Install the base with the new filter over the threads and turn clockwise until snug, but not too tight.
HAND TIGHTEN ONLY. DO NOT TIGHTEN WITH FILTER REPLACEMENT TOOL.
- Turn on COLD WATER ONLY. With a slight pull on the Diverter Button, allow water to run through the filter for approximately 15 minutes. The new filter is now fully activated and the Water Enhancement System is ready for use.
CAUTION: Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection of the system before or after. Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts.
Instructions for Under-Counter Water Dome®
Model #1720
Removing Used Filter Cartridge:
- Be sure water is turned off at shut-off valve. Place a large bowl or pan under Water Enhancement System to catch residual water.
- Open (black) ledge faucet lever to relieve pressure.
- Holding the unit base, unscrew black knob until band clamp can be removed. If this is awkward to do with the unit attached to the wall, unit may first be removed from mounting bracket and then opened. Remove band clamp. Separate unit base from upper housing and dump water into bowl or pan. Set unit base aside.
- Unthread used filter clockwise. Place used filter in a plastic bag and dispose of properly.
Installing a New Filter Cartridge:
- Gently wash inside of the housing unit with Liquid Concentrate, Mellow Yellow, or a liquid dishwashing detergent. Do not use harsh cleansers, solvents, ammonia, alcohol or acids to clean the unit. Rinse thoroughly to remove soap residue.
- Unwrap new filter and discard the small white rubber washer that comes with it. This is only used in the Countertop model. Carefully align new filter and turn counter-clockwise until snug, but not too tight.
CAUTION: As you are putting the unit back together, avoid damaging large O-ring. Check to see that it is positioned correctly before replacing band clamp.
- Replace bottom half of housing unit and tighten the band clamp.
- Turn on water at shut-off valve. Allow water to run through the filter for approximately 5 minutes as you carefully check all connections for leaks. Let water run for an additional 20 minutes to fully activate the filter cartridge. The Water Enhancement System is now ready for use.
CAUTION: Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection of the system before or after. Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts.
Amazing Health Products
Kerry Coates
P O Box 1005
Capitan, NM, USA 88316
(South of Santa Fe!)
575.354.2086
E-Mail

Authorized Distributor
© Copyright 2002-2009. Golden NeoLife Diamite Distributor
All rights reserved.
Contact the webmaster: Amazing Health Products
This site is labeled with ICRA.
GNLD Neolife's Water Dome Pure Water Filter System highly-compressed block of super-fine activated carbon efficiently removes unwanted contaminants and improves taste.